Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

HSA1960V1-**A: R-454B heat pump

Sold as Century, Comfort-Aire. R-454B Ducted split system, 4-ton class, in 82 ENERGY STAR certified pairings with 9 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
47,500 Btu/h
SEER2 range
16.5–18
HSPF2 range
7.8–8.2
Heat at 5°F
21,800–29,600 Btu/h
Cold-climate pairings
0 of 82
Compressor
Continuously variable
First certified
2025-07-03

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: HSA19 Series, HSA19 SERIES. ENERGY STAR partner: GE Appliances, a Haier Company.

Certified indoor matches

Top 30 of 82 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
7E[C,U]50/60CX-**+TDR
GUH80C110C5MP1811.28.223,600 Btu/hNo217504094
7E[C,U]50/60CX-**+TDR
GUH92C090C4MP1811.28.223,400 Btu/hNo217504096
7E[C,U]50/60CX-**+TDR
GUH96C090C4MP1811.28.223,400 Btu/hNo217504102
7E[C,U]50/60CX-**+TDR
GUH80C090B4MP1811.58.223,400 Btu/hNo217504208
7E[C,U]50/60CX-**+TDR
GUH80C110C5MP1811.28.223,600 Btu/hNo217504512
7E[C,U]50/60CX-**+TDR
GUH92C090C4MP1811.28.223,400 Btu/hNo217504513
7E[C,U]50/60CX-**+TDR
GUH96C090C4MP1811.28.223,400 Btu/hNo217504518
7E[C,U]50/60CX-**+TDR
GUH80C090B4MP1811.58.223,400 Btu/hNo217504603
7ED50/60CX-**+TDR
GDD92C090C4MP1811.2829,400 Btu/hNo217504236
7ED50/60CX-**+TDR
GDD80C110C5MP1811.7828,800 Btu/hNo217504235
7ED50/60CX-**+TDR
GDD80C110C5MP1811.7828,800 Btu/hNo217504628
7ED50/60CX-**+TDR
GDD92C090C4MP1811.2829,400 Btu/hNo217504630
7E[C,U]48BX-**+TDR
GUH80C090B4MP1811.77.822,000 Btu/hNo217504148
7E[C,U]48CX-**+TDR
GUH80C110C5MP1811.57.822,200 Btu/hNo217504114
7E[C,U]48CX-**+TDR
GUH92C090C4MP1811.57.822,000 Btu/hNo217504116
7E[C,U]48CX-**+TDR
GUH92C110C4MP1811.57.822,000 Btu/hNo217504119
7E[C,U]48CX-**+TDR
GUH96C090C4MP1811.57.822,000 Btu/hNo217504123
7E[C,U]48CX-**+TDR
GUH80C090B4MP1811.77.822,000 Btu/hNo217504213
7E[C,U]50/60CX-**+TDR
GUH97T090C3MP1811.27.823,200 Btu/hNo217547461
7E[C,U]50/60CX-**+TDR
GUH97T090C5MP*1811.27.823,800 Btu/hNo217547462
HMA48CX1*-**
—1811.77.823,400 Btu/hNo217662747
7E[C,U]48CX-**+TDR
GUH80C110C5MP1811.57.822,200 Btu/hNo217504529
7E[C,U]48CX-**+TDR
GUH92C090C4MP1811.57.822,000 Btu/hNo217504531
7E[C,U]48CX-**+TDR
GUH92C110C4MP1811.57.822,000 Btu/hNo217504532
7E[C,U]48CX-**+TDR
GUH96C090C4MP1811.57.822,000 Btu/hNo217504535
7E[C,U]48BX-**+TDR
GUH80C090B4MP1811.77.822,000 Btu/hNo217504554
7E[C,U]48CX-**+TDR
GUH80C090B4MP1811.77.822,000 Btu/hNo217504608
7E[C,U]50/60CX-**+TDR
GUH97T090C3MP1811.27.823,200 Btu/hNo217547488
7E[C,U]50/60CX-**+TDR
GUH97T090C5MP*1811.27.823,800 Btu/hNo217547489
HMA48CX1*-**
—1811.77.823,400 Btu/hNo217662744
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 4-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
BOHA-60MTB-M18SBosch16–19.58.1–10.131,000–45,000 Btu/h24
MDV-V48WMN10TMidea16–208.9–10.135,000–41,000 Btu/h7
MDV-V60WMN10T(B)Midea16–19.58.1–10.131,000–45,000 Btu/h22
249VAN048**AA*Bryant15.2–198.5–1036,000–41,500 Btu/h517
27VPA948A*030*Carrier15.2–198.5–1036,000–41,500 Btu/h534
5A6V0X48A1American Standard19.4–20.89.4–1032,600–34,800 Btu/h137
5TWV0X48A1Trane19.4–20.89.4–1032,600–34,800 Btu/h137
EODA19H-4860AB*Ecoer15.2–198.3–1028,000–38,500 Btu/h59

All 274 R-454B 4-ton units

More Century R-454B units

Next step