Outdoor unit · ENERGY STAR data November 12, 2026
4TWV8X36A1: R-410A heat pump
Sold as Trane. R-410A Ducted split system, 3-ton class, in 129 ENERGY STAR certified pairings with 22 indoor unit models.
- Refrigerant
- R-410A (GWP 2,088)
- Rated cooling
- 34,800 Btu/h
- SEER2 range
- 17.5–18
- HSPF2 range
- 7.8–8.5
- Heat at 5°F
- 19,200–21,000 Btu/h
- Cold-climate pairings
- 0 of 129
- Compressor
- Continuously variable
- First certified
- 2025-04-09
This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.
Series: XV18I, XV18. ENERGY STAR partner: Trane and American Standard Heating and Air Conditioning.
Certified indoor matches
Top 30 of 129 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
TAMXB0B30V31 | — | 18 | 12 | 8.5 | 20,400 Btu/h | No | 210929568 |
TAMXB0C36V31 | — | 18 | 12 | 8.5 | 20,000 Btu/h | No | 210929569 |
TEM8A0C42V41+TDR | — | 18 | 12 | 8.5 | 20,600 Btu/h | No | 207526354 |
4PX*CU48BS3 | S9V2C100U4VSA+RP | 18 | 12 | 8.5 | 20,400 Btu/h | No | 207526469 |
4PX*CU48BS3 | *UD2C100ACV5 | 18 | 12 | 8.5 | 20,400 Btu/h | No | 207526260 |
4PX*CU48BS3 | *UD2C080ACV4 | 18 | 12 | 8.5 | 20,200 Btu/h | No | 207526257 |
TEM8A0C36V31+TDR | — | 18 | 12 | 8.5 | 20,600 Btu/h | No | 207526353 |
4PX*CU42BS3 | S9V2C100U4VSA+RP | 18 | 12 | 8.5 | 20,400 Btu/h | No | 210653631 |
4PX*CU42BS3 | *UD2C080ACV4 | 18 | 12 | 8.5 | 20,200 Btu/h | No | 211596931 |
4PX*CU42BS3 | *UD2C100ACV5 | 18 | 12 | 8.5 | 20,400 Btu/h | No | 211289054 |
4PX*CU42BS3 | S9V2C080U5PSC+RP | 18 | 12 | 8.5 | 20,400 Btu/h | No | 214639993 |
4PX*CU48BS3 | S9V2C080U5PSC+RP | 18 | 12 | 8.5 | 20,400 Btu/h | No | 214639995 |
4TXCB006DS3 | S9V2B040U3PSC+RP | 18 | 12 | 8.5 | 21,000 Btu/h | No | 214640007 |
4TXCB006DS3 | S9V2B060U4PSC+RP | 18 | 12 | 8.5 | 20,600 Btu/h | No | 214640009 |
4PX*CU42BS3 | S9V2C080U5VSB+RP | 18 | 12.2 | 8.5 | 20,400 Btu/h | No | 215825873 |
4PX*CU48BS3 | S9V2C080U5VSB+RP | 18 | 12.2 | 8.5 | 20,400 Btu/h | No | 215825875 |
4PX*BU48BS3 | S9V2B080D4PSC+RP | 18 | 11.2 | 8.5 | 20,200 Btu/h | No | 214639981 |
4PX*BU48BS3 | S9V2B060D3PSC+RP | 18 | 11.2 | 8.5 | 20,200 Btu/h | No | 214639983 |
4PX*BU48BS3 | S9V2B040D3PSC+RP | 18 | 11.2 | 8.5 | 20,600 Btu/h | No | 214639985 |
4PX*CU36BS3 | S8V2C080M5PCA | 18 | 11.7 | 8.2 | 20,200 Btu/h | No | 210691884 |
4TXCC005DS3 | S8V2C080M5PCA | 18 | 11.7 | 8.2 | 20,200 Btu/h | No | 210691895 |
4TXCB006DS3 | *UD2B080ACV3 | 18 | 11.7 | 8.2 | 20,600 Btu/h | No | 209459221 |
4TXCB006DS3 | S8V2B060M4PDA | 18 | 12 | 8.2 | 20,600 Btu/h | No | 211081253 |
4PX*CU36BS3 | S8V2C100M5PDA | 18 | 11.7 | 8.2 | 20,400 Btu/h | No | 211081245 |
4PX*CU42BS3 | S8V2C100M5PDA | 18 | 12 | 8.2 | 20,400 Btu/h | No | 211081247 |
4TXCB006DS3 | S8V2B080M4PDA | 18 | 12 | 8.2 | 20,800 Btu/h | No | 211081254 |
4TXCC005DS3 | S8V2C100M5PDA | 18 | 11.7 | 8.2 | 20,400 Btu/h | No | 211081257 |
4TXCC005DS3 | S8V2C080M5PDA | 18 | 11.7 | 8.2 | 20,200 Btu/h | No | 211081256 |
4PX*CU48BS3 | S8V2C100M5PDA | 18 | 12 | 8.2 | 20,400 Btu/h | No | 211081249 |
4PX*CU36BS3 | S8V2C080M5PDA | 18 | 11.7 | 8.2 | 20,200 Btu/h | No | 211081244 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-410A 3-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
38MURAQ36AB3 | Bryant, Carrier +10 more | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 25 |
A-KCD36SA-1 | KERR | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 4 |
A-VCD36SA-1 | Comfort Aire, Comfort-Aire +1 more | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 11 |
ACIQ-36-HPB | 1HVAC, ACiQ +3 more | 15.2–17.6 | 8.6–10 | 31,600–36,000 Btu/h | 23 |
AZPN/36WD | Kepler | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 4 |
BMAH3618C | Blueridge | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 3 |
BZ33-INV36OUT2-J | Breeze33 | 15.2–17.6 | 8.6–10 | 31,600–33,400 Btu/h | 3 |
CCOXHA24V36HP | Custom Comfort | 15.2–16 | 8.6–10 | 31,600–34,400 Btu/h | 4 |