Refrigerant Finder

AC Pro R-454B heat pumps and mini-splits

All 49 AC Pro outdoor unit models on ENERGY STAR's list that use R-454B: 33 ducted, 16 mini or multi-split, 0 packaged, in 3,016 certified systems.

R-454B is a blend of R-32 and R-1234yf with a GWP of 470 in ENERGY STAR's data. Carrier, Bryant, Trane, American Standard, Rheem, Ruud, Bosch and many others moved their ducted lines to it when new R-410A split systems stopped being made on January 1, 2025. It is an A2L (mildly flammable) refrigerant, so the indoor coil or air handler must be designed and listed for it, and many systems need a refrigerant detection sensor.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
MHPC-H-009BSBMini/multi-split9,000 Btu19.7–2611.3–13.98,000–8,600 Btu/h55
MHPC-H-018BSBMini/multi-split18,000 Btu18.5–23.89.8–13.512,800–14,200 Btu/h66
MHPC-H-024BSBMini/multi-split24,000 Btu19–239–11.718,000–19,600 Btu/h44
MHPC-H-012BSBMini/multi-split12,000 Btu19.5–25.510–118,400–8,900 Btu/h55
SPHP-Z-V030BBDucted2.5-ton16.3–17.29.5–10.831,000–33,200 Btu/h22
MHPC-H-048BMBMini/multi-split48,000 Btu20.4–2410.3–10.636,000–38,000 Btu/h33
SPHP-Z-V018BBDucted1.5-ton16.3–199.3–10.518,000–19,000 Btu/h66
A7CP21V36P-**ADucted3-ton15.2–208.5–10.418,400–25,400 Btu/h327529
MHPC-H-036BSBMini/multi-split36,000 Btu2010.326,600 Btu/h11
A7CP21V24P-**ADucted2-ton15.2–217.8–10.213,900–18,600 Btu/h197391
MHPC-H-018BMBMini/multi-split18,000 Btu20–25.19.8–1013,500–14,600 Btu/h33
SPHP-Z-V024BBDucted2-ton16–18.68.9–1020,000–21,600 Btu/h66
SPHP-Z-V036BBDucted3-ton16.5–17.78.2–1032,000–32,600 Btu/h22
MHPC-H-048BSBMini/multi-split48,000 Btu17.1–19.19.8–9.938,000–40,500 Btu/h22
SPHP-Z-V037BBDucted3-ton15.49.836,000 Btu/h11
SPHP-Y-V024BBDucted2-ton16–18.18.9–9.719,000–21,600 Btu/h77
A7CP21V48P-**ADucted4-ton15.7–20.57.8–9.629,000–39,500 Btu/h248408
MHPC-H-027BMBMini/multi-split24,000 Btu21–259–9.518,800–19,000 Btu/h33
MHPC-H-036BMBMini/multi-split36,000 Btu20–249.2–9.526,000 Btu/h33
MHPC-H-012ASBMini/multi-split12,000 Btu23.49.57,700 Btu/h01
MHPC-H-030BSBMini/multi-split30,000 Btu17–20.58.7–9.520,000–20,400 Btu/h02
MHPC-J-030BSBMini/multi-split30,000 Btu20–20.59.2–9.519,700–20,000 Btu/h02
SPHP-Z-V048BBDucted4-ton15.2–17.58.3–9.541,000–48,000 Btu/h44
SPHP-Z-V060BBDucted4.5-ton15.7–17.58.4–9.541,000–54,000 Btu/h44
SPHP-B-36VBBDucted2.5-ton18.6–209–9.420,000–24,000 Btu/h22
MHPC-J-024BSBMini/multi-split24,000 Btu18.79.317,000 Btu/h11
MHPC-J-009BSBMini/multi-split9,000 Btu21.29.17,000 Btu/h11
SPHP-Y-V018BBDucted1.5-ton16.4–18.88.4–9.110,000–11,400 Btu/h03
MHPC-J-009ASBMini/multi-split9,000 Btu21.596,500 Btu/h01
A7CP21V60P-**ADucted4.5-ton16–20.58.1–931,600–38,500 Btu/h6244
SPHP-B-60VBBDucted4.5-ton17–17.58.6–934,200–42,500 Btu/h22
SPHP-Y-V048BBDucted4-ton15.2–168.1–938,000–41,000 Btu/h55
SPHP-Y-V036BBDucted3-ton15.4–16.18.2–8.726,000–28,400 Btu/h33
SPHP-Y-V060BBDucted4.5-ton15.2–15.58.4–8.638,000–40,000 Btu/h22
BH719M36P-**ADucted2-ton15.2–207.8–8.513,600–17,000 Btu/h0444
BH719M60P-**ADucted4-ton16.5–18.57.8–8.521,800–29,800 Btu/h0198
BH714S24P-**ADucted2-ton15.2–167.8–8.210,500–11,600 Btu/h0270
BH714S30P-**ADucted2.5-ton15.2–167.8–8.212,600–14,300 Btu/h063
BH714S48P-**ADucted4-ton15.27.8–8.123,800–24,200 Btu/h036
BH714S42P-**ADucted3.5-ton15.2–15.57.8–819,300–20,800 Btu/h0124
BH714S18P-**ADucted1.5-ton15.2–16.57.87,900–8,500 Btu/h0102
BH714S36P-**ADucted3-ton15.2–167.815,700–16,900 Btu/h086
SPHP-M-1018BBDucted1.5-ton15.27.87,200–7,500 Btu/h08
SPHP-M-1024BBDucted2-ton15.27.810,000–10,200 Btu/h07
SPHP-M-1030BBDucted2.5-ton15.27.811,600–12,100 Btu/h06
SPHP-M-1036BBDucted3-ton15.27.816,900 Btu/h02
SPHP-M-1042BBDucted3.5-ton15.27.820,200 Btu/h02
SPHP-M-1048BBDucted4-ton15.27.821,400–21,600 Btu/h03
SPHP-M-1061BBDucted4.5-ton15.27.828,000 Btu/h01

Other AC Pro refrigerants: AC Pro R-32 · AC Pro R-410A · all AC Pro models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step