Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

WP15AZ24AJ2N: R-410A heat pump

Sold as WeatherKing, Ruud, Rheem, Fujitsu. R-410A Ducted split system, 2-ton class, in 78 ENERGY STAR certified pairings with 13 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
22,800 Btu/h
SEER2 range
15.2–16
HSPF2 range
7.8–8.1
Heat at 5°F
11,500–13,200 Btu/h
Cold-climate pairings
38 of 78
Compressor
Two-stage
First certified
2023-05-03

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: VERSUS, CLASSIC PLUS, ACHIEVER PLUS. ENERGY STAR partner: Rheem Sales Company, Inc..

Certified indoor matches

Top 30 of 78 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
RCFZ2417STANM
R951V0703A17M4S1611.78.113,200 Btu/hYes212941604
RCFZ2417STANM
R951V0703A17M4S1611.78.113,200 Btu/hYes212941629
TCFZ2417STANM
W951W0703A17M4S1611.78.113,200 Btu/hYes212941601
RCFZ2417STANM
W951W0703A17M4S1611.78.113,200 Btu/hYes214326663
RCFZ2421MTANM
R951V0403A17UHU1611.77.811,900 Btu/hNo213372281
RCFZ2417MTANM
R951V0603A17UHU1611.77.812,000 Btu/hNo213372287
RCFZ2421MTANM
R951V0603A17UHU1611.77.811,800 Btu/hNo213372299
RCFZ2417MTANM
R951V0403A17UHU1611.77.812,000 Btu/hNo213372300
RH3VZ2417STACN
—1611.77.811,500 Btu/hNo214664598
RCFZ2421MTANM
R951V0603A17UHU1611.77.811,800 Btu/hNo213372279
RCFZ2421MTANM
R951V0403A17UHU1611.77.811,900 Btu/hNo213372290
RCFZ2417MTANM
R951V0403A17UHU1611.77.812,000 Btu/hNo213372292
RCFZ2417MTANM
R951V0603A17UHU1611.77.812,000 Btu/hNo213372295
RH3VZ2417STACN
—1611.77.811,500 Btu/hNo214664597
TCFZ2421MTANM
W951W0403A17UHU1611.77.811,900 Btu/hNo213372275
TCFZ2417MTANM
W951W0403A17UHU1611.77.812,000 Btu/hNo213372276
TCFZ2417MTANM
W951W0603A17UHU1611.77.812,000 Btu/hNo213372285
TCFZ2421MTANM
W951W0603A17UHU1611.77.811,800 Btu/hNo213372298
RCFZ2417MTANM
W951W0603A17UHU1611.77.812,000 Btu/hNo214326931
RCFZ2417MTANM
W951W0403A17UHU1611.77.812,000 Btu/hNo214326930
RCFZ2421MTANM
W951W0403A17UHU1611.77.811,900 Btu/hNo214326929
RCFZ2421MTANM
W951W0603A17UHU1611.77.811,800 Btu/hNo214326932
WH3VZ2417STANN
—1611.77.811,500 Btu/hNo214779511
FCCN2417SZTA
FF95SV304017M4S*A15.211.78.112,600 Btu/hYes212507741
FCCN2417SZTA
FF95SV306017UHU**A15.211.78.112,700 Btu/hYes212507742
FCCN2417SZTA
FF95SV306017M4S*A15.211.78.112,600 Btu/hYes212507744
FCCN2417SZTA
FF96TV304017M4S*A15.211.78.112,600 Btu/hYes212507759
FCCN2417SZTA
FF96TV307017M4S*A15.211.78.112,500 Btu/hYes212507760
FCCN2417SZTA
FF96TV306017M4S*A15.211.78.112,600 Btu/hYes212507761
RCFZ2417STANM
R96VA0702317M15.211.78.1—No212404551
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 2-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
ACIQ-24-HPB1HVAC, ACiQ +3 more16.1–199.3–10.520,000–24,000 Btu/h23
BZ33-INV24OUT2-JBreeze3316.1–17.59.5–10.520,000–24,000 Btu/h3
HHS-24HD-AMulti MFG17.4–199.3–10.522,600–24,000 Btu/h3
MOD30-24HFN1-MWMDV, Eco-air +4 more16.1–19.49.3–10.520,000–24,000 Btu/h19
SHV24H2R20Innovair16.1–199.3–10.520,000–24,000 Btu/h5
ACIQ-24-EHPB1HVAC, ACiQ +3 more15.7–179.2–10.218,500–19,400 Btu/h15
AZPN/24WDKepler16.1–17.49.5–10.220,000–22,600 Btu/h6
CDH2024C21CanAir16.1–17.49.5–10.220,000–22,600 Btu/h4

All 159 R-410A 2-ton units

More WeatherKing R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.