Outdoor unit · ENERGY STAR data November 12, 2026

T5H6S18*K*AAA*: R-454B heat pump

Sold as Tempstar. R-454B Ducted split system, 1.5-ton class, in 46 ENERGY STAR certified pairings with 10 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
18,100 Btu/h
SEER2 range
15.2–15.5
HSPF2 range
7.8–8
Heat at 5°F
8,200–8,500 Btu/h
Cold-climate pairings
0 of 46
Compressor
Single stage
First certified
2026-06-09

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: MAINLINE 16 SEER2 HP. ENERGY STAR partner: Carrier Corporation.

Certified indoor matches

Top 30 of 46 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FMA5X24**AL*
—15.512.588,200 Btu/hNo214423970
EVM5X32M17A*
*80MS(N,L)0701712A*15.5127.88,200 Btu/hNo214156830
EVM5X32M17A*
*80MS(N,L)0701716A*15.5127.88,200 Btu/hNo214156838
FM(C,U)5Z18**AL*
—15.21288,500 Btu/hNo215828878
FM(C,U)5Z24**AL*
—15.21288,500 Btu/hNo215828886
EA*5X25M17A*
*80VSL0451412B*15.2127.88,400 Btu/hNo214150718
EA*5X25M17A*
*80VSL0701716B*15.2127.88,400 Btu/hNo214150734
EA*5X25M17A*
*80ESU0401712A*15.2127.88,400 Btu/hNo214150750
EA*5X25M17A*
*80MSU0401712A*15.2127.88,400 Btu/hNo214150766
EA*5X25M17A*
*80MSU0601716A*15.2127.88,400 Btu/hNo214150774
EA*5X25M17A*
*80CTL0701412B*15.2127.88,400 Btu/hNo214150791
EA*5X25M17A*
*80CTL0701716B*15.2127.88,500 Btu/hNo214150799
EA*5X25M17A*
*80CTL0901716B*15.2127.88,500 Btu/hNo214150807
EA*5X25M17A*
*80VTL0451412B*15.2127.88,400 Btu/hNo214150823
EA*5X25M17A*
*80VTL0701716B*15.211.77.88,500 Btu/hNo214150831
EA*5X25M17A*
*92MSN0601714A*15.2127.88,400 Btu/hNo214150903
EA*5X25M17A*
*92MSN0801716A*15.2127.88,400 Btu/hNo214150911
EA*5X25M17A*
*96MSN0801716A*15.211.77.88,500 Btu/hNo214150927
EA*5X25M17A*
*95MSU0601716A*15.2127.88,500 Btu/hNo214150959
EA*5X25M17A*
*96CTN0801714B*15.2127.88,400 Btu/hNo214150975
EA*5X25M17A*
*96VTN0601716B*15.211.77.88,400 Btu/hNo214150999
EA*5X19M17A*
*80MSU0401712A*15.2127.88,400 Btu/hNo214150389
EA*5X19M17A*
*80MSU0601716A*15.2127.88,400 Btu/hNo214150397
EA*5X19M17A*
*80MS(N,L)0451412A*15.2127.88,400 Btu/hNo214150301
EA*5X19M17A*
*80VSL0451412B*15.211.77.88,400 Btu/hNo214150349
EA*5X19M17A*
*80VSL0701716B*15.211.77.88,400 Btu/hNo214150365
EA*5X19M17A*
*80ESU0401712A*15.2127.88,300 Btu/hNo214150373
EA*5X19M17A*
*80MS(N,L)0701412A*15.2127.88,400 Btu/hNo214150309
EA*5X19M17A*
*80MS(N,L)0701712A*15.2127.88,300 Btu/hNo214150317
EA*5X19M17A*
*80MS(N,L)0701716A*15.2127.88,400 Btu/hNo214150325
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 1.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
37MUHAQ18AA3Bryant, Carrier +3 more15.5–19.39.5–10.818,000–19,600 Btu/h33
A-VXP18SA-1Century, Comfort Aire +1 more16.1–19.39.5–10.818,000–19,600 Btu/h12
ACIQ-18-HPDACiQ, 1HVAC15.2–19.39.3–10.818,000–19,600 Btu/h17
AUO19-18N2-M3HAI Air Conditioning16.1–19.39.5–10.818,000–19,600 Btu/h6
CH-PQ18-230VOCooper&Hunter15.8–19.39.5–10.818,000–19,600 Btu/h5
CPH3-18CD(O)ComfortStar19–19.39.7–10.818,000–19,600 Btu/h3
D5CUHAH18AAKAirquest, Arcoaire +15 more15.5–19.39.5–10.818,000–19,600 Btu/h77
DRU1H18S2ADuraSTAR15.2–19.38.9–10.817,000–19,600 Btu/h43

All 153 R-454B 1.5-ton units

More Tempstar R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.