Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

SP14AY60AJ2N: R-454B heat pump

Sold as Sure, Russell. R-454B Ducted split system, 5-ton class, in 19 ENERGY STAR certified pairings with 4 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
57,000 Btu/h
SEER2 range
15.2
HSPF2 range
7.8
Heat at 5°F
25,800 Btu/h
Cold-climate pairings
0 of 19
Compressor
Two-stage
First certified
2024-04-16

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: VANTIX, CLASSIC SERIES. ENERGY STAR partner: Rheem Sales Company, Inc..

Certified indoor matches

Top 19 of 19 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
TCFY6021STAAM
S802V1005A21UH15.211.77.8—No214590661
TCFY6021STAAM
S801V1005A21UHS15.211.77.8—No214590626
TCFY6021STAAM
S801V1005A21UHN15.211.77.8—No214590629
TCFY6024STANM
S802V1255A24UH15.211.77.8—No214594648
TCFY6024STANM
S801V1255A24UH15.211.77.8—No214594653
TCFY6024STANM
S802V1005A21UH15.211.77.8—No214594669
TCFY6024STANM
S801V1005A21UHN15.211.77.8—No214594698
TCFY6024STANM
S801V1005A21UHS15.211.77.8—No214594700
SH2VY6024STACN
—15.211.77.8—No216030700
TCFY6021STAAM
S802V1005A21UH15.211.77.8—No214590671
TCFY6021STAAM
S801V1005A21UHS15.211.77.8—No214590634
TCFY6021STAAM
S801V1005A21UHN15.211.77.8—No214590640
TCFY6024STANM
S802V1005A21UH15.211.77.8—No214594614
TCFY6024STANM
S801V1005A21UHN15.211.77.8—No214594622
TCFY6024STANM
S801V1005A21UHS15.211.77.8—No214594626
TCFY6024STANM
S802V1255A24UH15.211.77.8—No214594646
TCFY6024STANM
S801V1255A24UH15.211.77.8—No214594654
SH2VY6024STACN
—15.211.77.8—No216030699
SH2CY6024STANN
—15.211.77.825,800 Btu/hNo218827204
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
AOH-60U3T24PHisense16.4–198.2–938,000–42,000 Btu/h3
AUWR-6024PHisense16.4–198.2–938,000–42,000 Btu/h3
ZE-660HPAZephyr16.4–198.2–938,000–42,000 Btu/h3
235SAN060**AA*Bryant15.27.828,600 Btu/h3
246SAN060**AA*Bryant15.27.828,600 Btu/h3
B5H6S60*K*AAA*Airquest, Arcoaire +6 more15.27.828,400 Btu/h8
C5H6S60*K*AAA*Comfortmaker, Day & Night +1 more15.27.828,400 Btu/h3
DRHP14B60AJ2ANDuraSTAR15.27.825,000–25,400 Btu/h15

All 35 R-454B 5-ton units

More Sure R-454B units

Next step