Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

RHP15036B21: R-410A heat pump

Sold as Evcon, Guardian. R-410A Ducted split system, 3-ton class, in 14 ENERGY STAR certified pairings with 7 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
35,000 Btu/h
SEER2 range
15.2
HSPF2 range
7.8
Heat at 5°F
17,700–18,500 Btu/h
Cold-climate pairings
2 of 14
Compressor
Two-stage
First certified
2026-07-14

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: LX SERIES. ENERGY STAR partner: Johnson Controls, Inc..

Certified indoor matches

Top 14 of 14 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
XAHC48FBCN1
RG19080C16MPS115.211.77.818,500 Btu/hYes214648020
XAHC36DBCN1+JME12C2SN1
—15.2127.818,200 Btu/hNo214799617
XAHC36DBCN1+JME16C2SN1
—15.2127.817,700 Btu/hNo214799624
XAFC48FBCN1+JME12C2SN1
—15.2127.818,000 Btu/hNo214799636
XAFD48FBCN1+JME18D2SN1
—15.2127.818,100 Btu/hNo214799660
XAHC48FBCN1+JME16C2SN1
—15.2127.817,700 Btu/hNo214799674
XAHD48FBCN1+JME18D2SN1
—15.2127.817,800 Btu/hNo214799696
XAHC48FBCN1
RG19080C16MPS115.211.77.818,500 Btu/hYes214648019
XAHC36DBCN1+JME12C2SN1
—15.2127.818,200 Btu/hNo214799616
XAHC36DBCN1+JME16C2SN1
—15.2127.817,700 Btu/hNo214799623
XAFC48FBCN1+JME12C2SN1
—15.2127.818,000 Btu/hNo214799635
XAFD48FBCN1+JME18D2SN1
—15.2127.818,100 Btu/hNo214799659
XAHC48FBCN1+JME16C2SN1
—15.2127.817,700 Btu/hNo214799673
XAHD48FBCN1+JME18D2SN1
—15.2127.817,800 Btu/hNo214799695
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ36AB3Bryant, Carrier +10 more15.2–168.6–1031,600–34,400 Btu/h25
A-KCD36SA-1KERR15.2–168.6–1031,600–34,400 Btu/h4
A-VCD36SA-1Comfort Aire, Comfort-Aire +1 more15.2–168.6–1031,600–34,400 Btu/h11
ACIQ-36-HPB1HVAC, ACiQ +3 more15.2–17.68.6–1031,600–36,000 Btu/h23
AZPN/36WDKepler15.2–168.6–1031,600–34,400 Btu/h4
BMAH3618CBlueridge15.2–168.6–1031,600–34,400 Btu/h3
BZ33-INV36OUT2-JBreeze3315.2–17.68.6–1031,600–33,400 Btu/h3
CCOXHA24V36HPCustom Comfort15.2–168.6–1031,600–34,400 Btu/h4

All 138 R-410A 3-ton units

More Evcon R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.