Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

QS15H30HA5***: R-454B heat pump

Sold as Haier. R-454B Ducted split system, 2.5-ton class, in 16 ENERGY STAR certified pairings with 10 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
29,300 Btu/h
SEER2 range
15.2–16.7
HSPF2 range
8.5–9.2
Heat at 5°F
19,000–20,000 Btu/h
Cold-climate pairings
0 of 16
Compressor
Continuously variable
First certified
2026-03-26

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: Connect 2026. ENERGY STAR partner: GE Appliances, a Haier Company.

Certified indoor matches

Top 16 of 16 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
NAM30V2TA5****
—16.711.49.219,200 Btu/hNo218382729
NAM36V2TA5****
—16.611.49.219,300 Btu/hNo218382730
NAM30V3TA5****
—16.611.19.219,300 Btu/hNo218382726
NCUC36BT5****+TDR
NF80U070V3BF***16.4118.520,000 Btu/hNo218685806
NAM36E1TA5****
—16.311919,500 Btu/hNo218382723
NAM30E1TA5****
—16.2118.719,500 Btu/hNo218382721
NCHC36CT5****+TDR
NF97U110V4CF***16.2118.719,700 Btu/hNo218685873
NCHC36CT5****+TDR
NF97U090V3CF***16.2118.719,700 Btu/hNo218685868
NCHC36CT5****+TDR
NF98U090M3C***16.2118.719,700 Btu/hNo218685031
NCHC36CT5****+TDR
NF97U090V3C***16.2118.719,700 Btu/hNo218685030
NCUC36BT5****+TDR
NF80U090V3BF***16.2118.520,000 Btu/hNo218685816
NCDC42BT5****+TDR
NF97D045V3BF***16.1118.719,700 Btu/hNo218685887
NAM30V1TA5****
—16118.819,000 Btu/hNo218078930
NAM36V1TA5****
—15.411.28.919,400 Btu/hNo218382724
NCHC36CT5****+TDR
NF80U110T4CF***15.3118.619,800 Btu/hNo218685872
NCHC36CT5****+TDR
NF93U110T4CF***15.2118.619,800 Btu/hNo218685874
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 2.5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
37MUHAQ30AA3Bryant, Carrier +3 more15.3–17.59.3–10.830,400–33,200 Btu/h35
ACIQ-30-HPDACiQ, 1HVAC15.3–17.58.7–10.828,000–33,200 Btu/h18
AHU3G-30HFN-BAproDr, ApooDr16.3–17.29.5–10.831,000–33,200 Btu/h3
AUO19-30N2-M3HAI Air Conditioning15.3–17.59.3–10.830,400–33,200 Btu/h7
BNG3A30UCNBlueridge15.3–17.29.3–10.830,400–33,200 Btu/h5
BZ33-INV30OUT2-454-G3-JBreeze3316–17.29.6–10.832,000–33,200 Btu/h4
CH-PQ33-230VOCooper&Hunter16–17.59.2–10.830,000–33,200 Btu/h6
CPH3-30CD(O)ComfortStar16.8–17.510–10.832,000–33,200 Btu/h3

All 176 R-454B 2.5-ton units

More Haier R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.