Outdoor unit · ENERGY STAR data November 12, 2026
MOVC-18HN10-M152L: R-454B heat pump
Sold as Midea. R-454B Ducted split system, 1.5-ton class, in 14 ENERGY STAR certified pairings with 14 indoor unit models.
- Refrigerant
- R-454B (GWP 470)
- Rated cooling
- 18,000 Btu/h
- SEER2 range
- 15.2
- HSPF2 range
- 7.8
- Heat at 5°F
- 7,200–7,600 Btu/h
- Cold-climate pairings
- 0 of 14
- Compressor
- Single stage
- First certified
- 2025-06-18
This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.
Series: M152H. ENERGY STAR partner: GD Midea Heating & Ventilating Equipment Co., Ltd..
Certified indoor matches
Top 14 of 14 pairings by SEER2. The AHRI number links to the ENERGY STAR record.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat at 5°F | Cold climate | AHRI ref # |
|---|---|---|---|---|---|---|---|
MHVE24A1MN10TB | — | 15.2 | 12 | 7.8 | 7,200 Btu/h | No | 217508463 |
MVME36B1MN10OA+TXV | — | 15.2 | 12 | 7.8 | 7,500 Btu/h | No | 217508466 |
MHVE18A1MN10TB | — | 15.2 | 12 | 7.8 | 7,200 Btu/h | No | 217508467 |
MVME24A1MN10OA+TXV | — | 15.2 | 12 | 7.8 | 7,500 Btu/h | No | 217508482 |
MPUE30B1MN10TA | — | 15.2 | 12 | 7.8 | 7,300 Btu/h | No | 217508483 |
MPCE30B1MN10TA | — | 15.2 | 12 | 7.8 | 7,300 Btu/h | No | 217508485 |
MPUE36B1MN10TA | — | 15.2 | 12 | 7.8 | 7,300 Btu/h | No | 217508484 |
MPCE36B1MN10TA | — | 15.2 | 12 | 7.8 | 7,300 Btu/h | No | 217508486 |
MVME24A1MN10TA | — | 15.2 | 12 | 7.8 | 7,500 Btu/h | No | 217508503 |
MVME36B1MN10TA | — | 15.2 | 12 | 7.8 | 7,500 Btu/h | No | 217508504 |
MPUE36B2MN10TA | — | 15.2 | 12 | 7.8 | 7,600 Btu/h | No | 218043532 |
MPUE30B2MN10TA | — | 15.2 | 12 | 7.8 | 7,600 Btu/h | No | 218043531 |
MPCE36B2MN10TA | — | 15.2 | 12 | 7.8 | 7,600 Btu/h | No | 218043520 |
MPCE30B2MN10TA | — | 15.2 | 12 | 7.8 | 7,600 Btu/h | No | 218043519 |
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.
Other R-454B 1.5-ton units
| Outdoor unit | Brand | SEER2 | HSPF2 | Heat at 5°F | Certified pairings |
|---|---|---|---|---|---|
37MUHAQ18AA3 | Bryant, Carrier +3 more | 15.5–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 33 |
A-VXP18SA-1 | Century, Comfort Aire +1 more | 16.1–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 12 |
ACIQ-18-HPD | ACiQ, 1HVAC | 15.2–19.3 | 9.3–10.8 | 18,000–19,600 Btu/h | 17 |
AUO19-18N2-M3H | AI Air Conditioning | 16.1–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 6 |
CH-PQ18-230VO | Cooper&Hunter | 15.8–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 5 |
CPH3-18CD(O) | ComfortStar | 19–19.3 | 9.7–10.8 | 18,000–19,600 Btu/h | 3 |
D5CUHAH18AAK | Airquest, Arcoaire +15 more | 15.5–19.3 | 9.5–10.8 | 18,000–19,600 Btu/h | 77 |
DRU1H18S2A | DuraSTAR | 15.2–19.3 | 8.9–10.8 | 17,000–19,600 Btu/h | 43 |