Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

FWP15AY60AJ2N: R-454B heat pump

Sold as Friedrich. R-454B Ducted split system, 5-ton class, in 17 ENERGY STAR certified pairings with 5 indoor unit models.

Refrigerant
R-454B (GWP 470)
Rated cooling
57,000 Btu/h
SEER2 range
15.2
HSPF2 range
7.8
Heat at 5°F
—
Cold-climate pairings
0 of 17
Compressor
Two-stage
First certified
2024-08-28

This unit uses R-454B, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-454B, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: VERSUS. ENERGY STAR partner: Rheem Sales Company, Inc..

Certified indoor matches

Top 17 of 17 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
FRH2TY6024STANN
—15.211.77.8—No215415479
TCFY6021STAAM
FR801V1005A21UHN15.211.77.8—No215657520
TCFY6021STAAM
FR801V1005A21UHS15.211.77.8—No215657557
TCFY6021STAAM
FR802V1005A21UH15.211.77.8—No215657594
TCFY6024STANM
FR801V1255A24UH15.211.77.8—No215656242
TCFY6024STANM
FR802V1255A24UH15.211.77.8—No215656325
TCFY6024STANM
FR801V1005A21UHS15.211.77.8—No215656341
TCFY6024STANM
FR801V1005A21UHN15.211.77.8—No215656354
TCFY6024STANM
FR802V1005A21UH15.211.77.8—No215656369
RCFY6024STANM
FR802V1255A24UH15.211.77.8—No216545075
RCFY6024STANM
FR802V1005A21UH15.211.77.8—No216544762
RCFY6024STANM
FR801V1255A24UH15.211.77.8—No216543271
RCFY6024STANM
FR801V1005A21UHN15.211.77.8—No216543324
RCFY6024STANM
FR801V1005A21UHS15.211.77.8—No216543333
RCFY6021STAAM
FR801V1005A21UHS15.211.77.8—No216543338
RCFY6021STAAM
FR801V1005A21UHN15.211.77.8—No216543340
RCFY6021STAAM
FR802V1005A21UH15.211.77.8—No216544885
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-454B 5-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
AOH-60U3T24PHisense16.4–198.2–938,000–42,000 Btu/h3
AUWR-6024PHisense16.4–198.2–938,000–42,000 Btu/h3
ZE-660HPAZephyr16.4–198.2–938,000–42,000 Btu/h3
235SAN060**AA*Bryant15.27.828,600 Btu/h3
246SAN060**AA*Bryant15.27.828,600 Btu/h3
B5H6S60*K*AAA*Airquest, Arcoaire +6 more15.27.828,400 Btu/h8
C5H6S60*K*AAA*Comfortmaker, Day & Night +1 more15.27.828,400 Btu/h3
DRHP14B60AJ2ANDuraSTAR15.27.825,000–25,400 Btu/h15

All 35 R-454B 5-ton units

More Friedrich R-454B units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.