Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

EODA17H-2436AD*: R-32 heat pump

Sold as Ecoer. R-32 Ducted split system, 3-ton class, in 26 ENERGY STAR certified pairings with 5 indoor unit models.

Refrigerant
R-32 (GWP 675)
Rated cooling
33,000 Btu/h
SEER2 range
15.2–18.5
HSPF2 range
8.1–8.8
Heat at 5°F
18,000–24,000 Btu/h
Cold-climate pairings
20 of 26
Compressor
Continuously variable
First certified
2025-11-24

This unit uses R-32, an A2L refrigerant. It has to be paired with an indoor coil or air handler designed and listed for R-32, like the certified matches below. It can't be connected to an existing R-410A coil or charged with R-410A. Why.

Series: TDi Select 2. ENERGY STAR partner: Ecoer Inc..

Certified indoor matches

Top 26 of 26 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
EAHDEN-24BE*
—18.5128.818,000 Btu/hYes218004216
EAHDEN-36BE*
—17.5118.824,000 Btu/hYes218004217
EACE2430BE*
EVMF98M28080B3L17.511.78.718,000 Btu/hYes218004221
EACE2430BE*
MGV80M060B4A17.511.78.718,000 Btu/hYes218066989
EACE2430BE*
MGV80M080B4A17.511.78.718,000 Btu/hYes218066988
EACE2430BE*
MGV96U060B3C17.511.78.718,000 Btu/hYes218066980
EACE2430BE*
MGV96U080B3C17.511.78.718,000 Btu/hYes218066979
EACE2430BE*
MGH96M080B3A17.511.78.718,000 Btu/hYes218396780
EACE2430BE*
FG7TC-060D-V24B*17.511.78.718,000 Btu/hYes218396772
EACE3036BE*
EVMF98M28080B3L16.510.28.724,000 Btu/hYes218004222
EACE4248CE*
EVMF98M35100C5L16.5118.722,400 Btu/hNo218004223
EACE3036BE*
MGV80M060B4A16.510.28.724,000 Btu/hYes218066991
EACE3036BE*
MGV80M080B4A16.510.28.724,000 Btu/hYes218066990
EACE4248CE*
MGV96U080C4C16.5118.722,400 Btu/hNo218066983
EACE3036BE*
MGV96U060B3C16.510.28.724,000 Btu/hYes218066982
EACE3036BE*
MGV96U080B3C16.510.28.724,000 Btu/hYes218066981
EACE4248CE*
MGH96M080C4A16.5118.722,400 Btu/hNo218396783
EACE3036BE*
MGH96M080B3A16.510.28.724,000 Btu/hYes218396781
EACE4248CE*
FG7TC-080D-V35C*16.5118.722,400 Btu/hNo218396775
EACE4248CE*
FG7TC-100D-V35C*16.5118.722,400 Btu/hNo218396774
EACE3036BE*
FG7TC-060D-V24B*16.510.28.724,000 Btu/hYes218396773
EACE2430BE*
FG7SA-072C-T24B*1611.78.118,000 Btu/hYes218423697
EACE2430BE*
FG7SA-090C-T24B*1611.78.118,000 Btu/hYes218423696
EACE4248CE*
MGH96M100C5A15.5118.522,400 Btu/hNo218396782
EACE3036BE*
FG7SA-072C-T24B*15.210.28.124,000 Btu/hYes218423699
EACE3036BE*
FG7SA-090C-T24B*15.210.28.124,000 Btu/hYes218423698
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-32 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
KUSXA361ALG15.5–23.58.9–10.533,000–36,000 Btu/h9
KUSXB361ALG15.2–228.4–10.332,000–35,000 Btu/h9
ACIQ-36-HP321HVAC, ACiQ +2 more181034,000 Btu/h4
AZV9SA361CA*Amana16.9–218.5–1031,000–34,200 Btu/h33
DH9VSA361CA*Daikin16.9–218.5–1031,000–34,200 Btu/h33
GZV9SA361CA*Goodman16.9–218.5–1031,000–34,200 Btu/h31
TU36W-EDUTOSOT18–18.21024,000–34,000 Btu/h3
VHP-UCHA-36HDCT-AVillaTherm18–18.59–1025,000–25,600 Btu/h5

All 44 R-32 3-ton units

More Ecoer R-32 units