Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

BHP17L36P-**A: R-410A heat pump

Sold as Blueridge. R-410A Ducted split system, 3-ton class, in 131 ENERGY STAR certified pairings with 26 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
36,000 Btu/h
SEER2 range
15.2–16.8
HSPF2 range
7.8–8.7
Heat at 5°F
16,800–19,100 Btu/h
Cold-climate pairings
0 of 131
Compressor
Single stage
First certified
2025-10-27

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: BHP17 Series, BHP17L SERIES, BHP17L Series. ENERGY STAR partner: Lennox Industries.

Certified indoor matches

Top 30 of 131 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
BC748CCT-0*+TDR
BG801UH090CE2016.813.57.816,800 Btu/hNo214713501
BC748DCT-0*+TDR
BG80G1DF110CE2016.6138.718,800 Btu/hNo214713481
BH1P51C*+TDR+TXV
BG801UH090CE2016.613.5817,400 Btu/hNo211736686
BC742HCT-0*+TDR
BG921UH110CE1616.613.5817,900 Btu/hNo214713449
BC742HCT-0*+TDR
BG961UH110CE2016.613.5817,800 Btu/hNo214713452
BC748CCT-0*+TDR
BG801UH110CE2016.613.5817,000 Btu/hNo214713502
BC751HCT-0*+TDR
BG801UH090CE2016.613.5817,400 Btu/hNo214713464
BC4X36B+TDR
BG801UH090BE1616.613.57.816,800 Btu/hNo210441335
BC1P36B+TDR+TXV
BG801UH090BE1616.613.57.816,800 Btu/hNo210441308
BC1P36A+TDR+TXV
BG801UH090BE1616.613.57.816,800 Btu/hNo210325358
BC748CCT-0*+TDR
BG921UH090CE1616.613.57.816,800 Btu/hNo214713504
BC748CCT-0*+TDR
BG921UH110CE1616.613.57.817,000 Btu/hNo214713505
BC748CCT-0*+TDR
BG921UH110CE2016.613.57.816,800 Btu/hNo214713506
BC748CCT-0*+TDR
BG961UH090CE1616.613.57.817,000 Btu/hNo214713507
BC748CCT-0*+TDR
BG961UH110CE2016.613.57.817,000 Btu/hNo214713508
BC736CBT-0*+TDR
BG801UH090BE1616.613.57.816,800 Btu/hNo214713493
BH1P51C*+TDR+TXV
BG801UH110CE2016.4138.117,400 Btu/hNo211736699
BC742HCT-0*+TDR
BG801UH110CE2016.413.58.118,000 Btu/hNo214713446
BC742HBT-0*+TDR
BG801UH090BE1616.4138.118,300 Btu/hNo214713439
BC751HCT-0*+TDR
BG801UH110CE2016.4138.117,400 Btu/hNo214713465
BH1P51C*+TDR+TXV
BG921UH110CE2016.413817,300 Btu/hNo211736762
BH1P51C*+TDR+TXV
BG961UH110CE2016.413817,500 Btu/hNo211736794
BC742HCT-0*+TDR
BG921UH110CE2016.413.5817,900 Btu/hNo214713450
BC742HCT-0*+TDR
BG961UH090CE1616.413.5818,100 Btu/hNo214713451
BC742HCT-0*+TDR
BG801UH090CE2016.413.5817,900 Btu/hNo214713445
BC751HCT-0*+TDR
BG921UH110CE2016.413817,300 Btu/hNo214713469
BC751HCT-0*+TDR
BG961UH110CE2016.413817,500 Btu/hNo214713471
BC742HCT-0*+TDR
BG921UH090CE1616.413.5817,900 Btu/hNo214713448
BC4X36B+TDR
BG802UH090BE1616.4137.817,000 Btu/hNo210441332
BC1P36B+TDR+TXV
BG802UH090BE1616.4137.817,000 Btu/hNo210441305
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ36AB3Bryant, Carrier +10 more15.2–168.6–1031,600–34,400 Btu/h25
A-KCD36SA-1KERR15.2–168.6–1031,600–34,400 Btu/h4
A-VCD36SA-1Comfort Aire, Comfort-Aire +1 more15.2–168.6–1031,600–34,400 Btu/h11
ACIQ-36-HPB1HVAC, ACiQ +3 more15.2–17.68.6–1031,600–36,000 Btu/h23
AZPN/36WDKepler15.2–168.6–1031,600–34,400 Btu/h4
BMAH3618CBlueridge15.2–168.6–1031,600–34,400 Btu/h3
BZ33-INV36OUT2-JBreeze3315.2–17.68.6–1031,600–33,400 Btu/h3
CCOXHA24V36HPCustom Comfort15.2–168.6–1031,600–34,400 Btu/h4

All 138 R-410A 3-ton units

More Blueridge R-410A units