Refrigerant Finder
Outdoor unit · ENERGY STAR data November 12, 2026

ACIQ-36-HPC: R-410A heat pump

Sold as 1HVAC, ACiQ, Diycool, PolarWave +1 more. R-410A Ducted split system, 3-ton class, in 15 ENERGY STAR certified pairings with 3 indoor unit models.

Refrigerant
R-410A (GWP 2,088)
Rated cooling
35,000 Btu/h
SEER2 range
15.2–16.3
HSPF2 range
8.5–9.5
Heat at 5°F
30,000–38,000 Btu/h
Cold-climate pairings
15 of 15
Compressor
Continuously variable
First certified
2026-06-09

This is an R-410A unit. New R-410A split systems stopped being made or imported on January 1, 2025. Under EPA's May 2026 rule, a complete system can still be installed only if every component was made or imported before 2025, and a newer R-410A condensing unit must be labeled "For servicing existing equipment only". State rules can be stricter. What that means for a quote.

Series: ACIQ series, ACIQ-series. ENERGY STAR partner: 1HVAC Energy, LLC.

Certified indoor matches

Top 15 of 15 pairings by SEER2. The AHRI number links to the ENERGY STAR record.

Indoor unitFurnaceSEER2EER2HSPF2Heat at 5°FCold climateAHRI ref #
ACIQ-36-AHB*
—16.311.79.538,000 Btu/hYes213500936
ACIQ-36-AHB*
—16.311.79.538,000 Btu/hYes213500937
ACIQ-36-AHB*
—16.311.79.538,000 Btu/hYes213500938
ACIQ-36-AHB*
—16.311.79.538,000 Btu/hYes213500939
ACIQ-36-AHB*
—16.311.79.538,000 Btu/hYes213500940
ACIQ-36-ACL-17
—15.2108.530,000 Btu/hYes213492118
ACIQ-36-ACL
—15.2108.530,000 Btu/hYes213492120
ACIQ-36-ACL-17
—15.2108.530,000 Btu/hYes213492131
ACIQ-36-ACL
—15.2108.530,000 Btu/hYes213492132
ACIQ-36-ACL-17
—15.2108.530,000 Btu/hYes213492142
ACIQ-36-ACL
—15.2108.530,000 Btu/hYes213492143
ACIQ-36-ACL-17
—15.2108.530,000 Btu/hYes213492154
ACIQ-36-ACL
—15.2108.530,000 Btu/hYes213492155
ACIQ-36-ACL-17
—15.2108.530,000 Btu/hYes213492163
ACIQ-36-ACL
—15.2108.530,000 Btu/hYes213492165
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Other R-410A 3-ton units

Outdoor unitBrandSEER2HSPF2Heat at 5°FCertified pairings
38MURAQ36AB3Bryant, Carrier +10 more15.2–168.6–1031,600–34,400 Btu/h25
A-KCD36SA-1KERR15.2–168.6–1031,600–34,400 Btu/h4
A-VCD36SA-1Comfort Aire, Comfort-Aire +1 more15.2–168.6–1031,600–34,400 Btu/h11
ACIQ-36-HPB1HVAC, ACiQ +3 more15.2–17.68.6–1031,600–36,000 Btu/h23
AZPN/36WDKepler15.2–168.6–1031,600–34,400 Btu/h4
BMAH3618CBlueridge15.2–168.6–1031,600–34,400 Btu/h3
BZ33-INV36OUT2-JBreeze3315.2–17.68.6–1031,600–33,400 Btu/h3
CCOXHA24V36HPCustom Comfort15.2–168.6–1031,600–34,400 Btu/h4

All 138 R-410A 3-ton units

More 1HVAC R-410A units

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.