Truenorth heat pump refrigerants: R-32 / R-410A

Truenorth has 35 ENERGY STAR certified outdoor unit models (24 R-32, 11 R-410A) in 140 certified systems.

R-32 24 (69%)R-410A 11 (31%)
Main refrigerant
R-32
Outdoor models
35
Ducted / mini / packaged
16 / 19 / 0
Certified systems
140

Some of these outdoor units are also listed under GREE, AC Pro.

Which refrigerant a Truenorth system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.

Truenorth R-32 outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
GUD60W2/NHE-D(U)Ducted4-ton16–199–10.548,000–54,000 Btu/h14
WLUD60W2/NHE-D(U)Ducted4-ton16–199–10.548,000–54,000 Btu/h6
WLWHD(18)ND6MOMini/multi-split18,000 Btu16–218.1–1013,600–13,800 Btu/h3
WLWHD(24)ND6MOMini/multi-split24,000 Btu18–218.1–1021,600 Btu/h3
WLWHD(30)ND6MOMini/multi-split30,000 Btu18–218.1–1026,000–27,000 Btu/h3
WLWHD(36)ND6MOMini/multi-split36,000 Btu18–218.1–1033,000–36,000 Btu/h3
WLWHD(42)ND6MOMini/multi-split42,000 Btu18–218.1–1036,000–37,800 Btu/h3
WLWHD(60)ND6MOMini/multi-split60,000 Btu19–218–1031,000–36,400 Btu/h3
GUD48W2/NHE-D(U)Ducted4-ton191048,000 Btu/h4
WLUD48W2/NHE-D(U)Ducted4-ton191048,000 Btu/h2
GUD36W2/NHE-D(U)Ducted2.5-ton16–18.28.5–1024,000–34,000 Btu/h14
WLUD36W2/NHE-D(U)Ducted2.5-ton16–18.28.5–1024,000–34,000 Btu/h7
GUD24W2/NHE-D(U)Ducted2-ton181024,000–25,000 Btu/h4
WLUD24W2/NHE-D(U)Ducted2-ton181024,000–25,000 Btu/h2
GUD60W2/NHG-D(U)Ducted4-ton18.8–209.536,000–40,000 Btu/h4
WLUD60W2/NHG-D(U)Ducted4-ton18.8–209.536,000–40,000 Btu/h2
GUD18W2/NHE-D(U)Ducted1.5-ton18917,000–18,000 Btu/h3
WLUD18W2/NHE-D(U)Ducted1.5-ton18917,000 Btu/h1
WLWH09ATCXB-D6DNA4D/OMini/multi-split9,000 Btu20.58.87,600 Btu/h1
WLWH18ATDXD-D6DNA4F/OMini/multi-split18,000 Btu208.512,100 Btu/h1
WLWH12ATCXB-D6DNA4B/OMini/multi-split12,000 Btu198.59,100 Btu/h1
WLWH24ATEXF-D6DNA4H/OMini/multi-split24,000 Btu198.516,800 Btu/h1
GUD36W2/NHG-D(U)Ducted2-ton16–18.58.3–8.517,000–21,600 Btu/h3
WLUD36W2/NHG-D(U)Ducted2.5-ton16–18.58.3–8.517,000–21,600 Btu/h2

Truenorth R-410A outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
WLWHD(18)ND3MOMini/multi-split18,000 Btu16–218.1–1013,600–14,000 Btu/h5
WLWHD(18)ND3POMini/multi-split18,000 Btu16–218.1–1013,400–13,600 Btu/h6
WLWHD(24)ND3MOMini/multi-split24,000 Btu16–218.1–1021,600–23,000 Btu/h6
WLWHD(30)ND3MOMini/multi-split30,000 Btu16–218.1–1022,800–26,800 Btu/h6
WLWHD(36)ND3MOMini/multi-split36,000 Btu16–218.1–1030,000–32,400 Btu/h6
WLWHD(42)ND3MOMini/multi-split36,000 Btu16–218.1–1032,400 Btu/h6
WLUD36W/A-D(U)Ducted2.5-ton15.2–178.5–921,600–28,000 Btu/h8
WLUD60W/A-D(U)Ducted4-ton16–17939,000–41,000 Btu/h4
WLW09HQ19SDOMini/multi-split9,000 Btu19.58.87,400 Btu/h1
WLW12HQ19SAOMini/multi-split12,000 Btu17.58.58,500 Btu/h1
WLW12HQ19SDOMini/multi-split12,000 Btu17.58.58,500 Btu/h1
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.