TGM · ENERGY STAR data November 12, 2026

TGM heat pump refrigerants: R-454B / R-32 / R-410A

TGM has 30 ENERGY STAR certified outdoor unit models (4 R-454B, 12 R-32, 14 R-410A) in 59 certified systems.

R-454B 4 (13%)R-32 12 (40%)R-410A 14 (47%)
Main refrigerant
R-410A
Outdoor models
30
Ducted / mini / packaged
2 / 28 / 0
Certified systems
59

Which refrigerant a TGM system uses depends on the exact outdoor model, not the brand. Check the model below or in the lookup, and make sure the indoor coil or air handler on your quote is certified with it.

TGM R-454B outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
MRS5VHT18ASMini/multi-split18,000 Btu20–22.310.4–11.412,800–14,200 Btu/h3
MRS5VHT24ASMini/multi-split24,000 Btu19–2210.5–11.118,500–19,000 Btu/h3
MRS5VHT36ASMini/multi-split36,000 Btu2010.326,600 Btu/h1
MRS5VHT48ASMini/multi-split48,000 Btu17.1–19.89.8–10.238,000–40,500 Btu/h3

TGM R-32 outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
ARHHBT18ASMini/multi-split18,000 Btu2510.515,000 Btu/h1
ARHHBT24ASMini/multi-split24,000 Btu2510.520,400 Btu/h1
ARHHBT12ASMini/multi-split12,000 Btu24108,900 Btu/h1
ARHHBT12ASAMini/multi-split12,000 Btu24109,300 Btu/h1
GMRSHT18AS2Mini/multi-split18,000 Btu16–218.1–1013,600–13,800 Btu/h3
GMRSHT24AS3Mini/multi-split24,000 Btu18–218.1–1021,600 Btu/h3
GMRSHT36AS4Mini/multi-split36,000 Btu18–218.1–1033,000–36,000 Btu/h3
GMRSHT42AS5Mini/multi-split42,000 Btu18–218.1–1036,000–37,800 Btu/h3
GRH32IT12ASMini/multi-split12,000 Btu21.58.59,400 Btu/h1
GRH32IT12ASAMini/multi-split12,000 Btu21.58.58,500 Btu/h1
GRH32IT18ASMini/multi-split18,000 Btu21.58.513,000 Btu/h1
GRH32IT36ASMini/multi-split36,000 Btu218.523,400–24,600 Btu/h2

TGM R-410A outdoor units

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCertified pairings
MRSVHT24ASMini/multi-split24,000 Btu19–21.59.7–11.218,200–20,000 Btu/h3
MRSVHT18ASMini/multi-split18,000 Btu20–20.510.5–10.612,700–13,000 Btu/h3
MRAPT12ASMini/multi-split12,000 Btu25.510.412,000 Btu/h2
MRSVHT12ASMini/multi-split12,000 Btu19–22.710–10.38,000–8,400 Btu/h3
MMRSHT18AS2Mini/multi-split18,000 Btu19–219.8–10.212,600–13,300 Btu/h3
MC4VHT18SMini/multi-split18,000 Btu231013,000 Btu/h1
MRAPT24ASMini/multi-split24,000 Btu221015,500 Btu/h1
MRSVHT48ASMini/multi-split48,000 Btu18.91035,000 Btu/h1
MMRSHT48AS5Mini/multi-split48,000 Btu21.19.533,000 Btu/h1
MMRSHT27AS3Mini/multi-split30,000 Btu21–23.59.218,700–19,000 Btu/h3
MMRSHT36AS4Mini/multi-split36,000 Btu209.224,000 Btu/h1
GTS18HN036ADucted2.5-ton16–17922,000–28,000 Btu/h2
GTS18HN060ADucted4-ton16–17939,000–41,000 Btu/h2
MRPOT30ASMini/multi-split30,000 Btu218.218,400 Btu/h2
Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step