Refrigerant Finder

TCL R-454B heat pumps and mini-splits

All 66 TCL outdoor unit models on ENERGY STAR's list that use R-454B: 19 ducted, 47 mini or multi-split, 0 packaged, in 356 certified systems.

R-454B is a blend of R-32 and R-1234yf with a GWP of 470 in ENERGY STAR's data. Carrier, Bryant, Trane, American Standard, Rheem, Ruud, Bosch and many others moved their ducted lines to it when new R-410A split systems stopped being made on January 1, 2025. It is an A2L (mildly flammable) refrigerant, so the indoor coil or air handler must be designed and listed for it, and many systems need a refrigerant detection sensor.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
H27FMHD4XPCMini/multi-split24,000 Btu22–26.510.525,000–26,000 Btu/h33
TMH27HEI2NAS0U25Mini/multi-split24,000 Btu26.510.526,000 Btu/h11
TMH27HEI2NAS0U25*Mini/multi-split24,000 Btu22–26.510.525,000–26,000 Btu/h33
H09SUH25XGCMini/multi-split9,000 Btu2510.59,500 Btu/h11
H12SUH25XGCMini/multi-split12,000 Btu2510.512,000 Btu/h11
TSH09HEI2NAP0T24UMini/multi-split9,000 Btu2510.59,100 Btu/h11
TSH12HEI2NAP0T24UMini/multi-split12,000 Btu2510.512,000 Btu/h11
H18FMH22XPCMini/multi-split18,000 Btu20–249–10.515,000–16,000 Btu/h33
H27FMH22XPCMini/multi-split24,000 Btu21–249–10.518,900–19,800 Btu/h22
TMH18HEI2NAO0U24Mini/multi-split18,000 Btu20–249–10.515,000–16,000 Btu/h33
TMH27HEI2NAO0U24Mini/multi-split24,000 Btu21–249–10.518,900–19,800 Btu/h22
H09SBH23XPCMini/multi-split9,000 Btu19.6–239.5–10.57,100–7,400 Btu/h33
TSH09HEI2NAO0T24*Mini/multi-split9,000 Btu19.6–239.5–10.57,100–7,400 Btu/h44
H36FMH21XPCMini/multi-split36,000 Btu20.5–22.59–10.525,000–26,000 Btu/h33
TMH36HEI2NAM5U24Mini/multi-split36,000 Btu20.5–22.59–10.525,000–26,000 Btu/h33
TSH24HEI2NAN0T24*Mini/multi-split24,000 Btu19–239.5–10.418,500–19,200 Btu/h55
H18FMHD3XPCMini/multi-split18,000 Btu21.5–279–1018,900–19,800 Btu/h33
TMH18HEI2NAS0U25Mini/multi-split18,000 Btu271019,800 Btu/h11
TMH18HEI2NAS0U25*Mini/multi-split18,000 Btu21.5–279–1018,900–19,800 Btu/h33
H36FMHD5XPCMini/multi-split36,000 Btu20–259–1030,000–33,000 Btu/h33
TMH36HEI2NAS0U25Mini/multi-split36,000 Btu251030,000 Btu/h11
TMH36HEI2NAS0U25*Mini/multi-split36,000 Btu20–259–1030,000–33,000 Btu/h33
H12SBH23XPCMini/multi-split12,000 Btu19–248.4–108,800–9,100 Btu/h33
H48FMHD6XPCMini/multi-split48,000 Btu20–249–1041,000–42,000 Btu/h33
TMH48HEI2NAS0U25Mini/multi-split48,000 Btu241042,000 Btu/h11
TMH48HEI2NAS0U25*Mini/multi-split48,000 Btu20–249–1041,000–42,000 Btu/h33
TSH12HEI2NAO0T24*Mini/multi-split12,000 Btu19–248.4–108,800–9,100 Btu/h44
H18SUH23XGCMini/multi-split18,000 Btu23.51017,800 Btu/h11
TSH18HEI2NAN5T24UMini/multi-split18,000 Btu23.51017,800 Btu/h11
H12SBH22BPCMini/multi-split12,000 Btu23108,900 Btu/h11
H18SBH22XPCMini/multi-split18,000 Btu20–238.5–1013,200–19,200 Btu/h55
H24SBH20XPCMini/multi-split24,000 Btu19–239–1013,800–19,300 Btu/h55
H24SUH23XGCMini/multi-split24,000 Btu239.5–1018,600–22,400 Btu/h22
TSH12HEI1NAN0T24*Mini/multi-split12,000 Btu23108,900 Btu/h11
TSH18HEI2NAN0T24*Mini/multi-split18,000 Btu20.3–238.5–1013,200–13,600 Btu/h55
TSH24HEI2NAN0T24UMini/multi-split24,000 Btu22.51022,400 Btu/h11
H42FMH20XPCMini/multi-split42,000 Btu19.5–229–1030,000–33,000 Btu/h33
TMH42HEI2NAM0U24Mini/multi-split42,000 Btu19.5–229–1030,000–33,000 Btu/h33
H09SEH19XACMini/multi-split9,000 Btu20107,400 Btu/h11
TSH09HEI2NAK0X24*Mini/multi-split9,000 Btu20107,400 Btu/h11
H09SBH23BPCMini/multi-split9,000 Btu239.57,100 Btu/h11
TSH09HEI1NAO0T24*Mini/multi-split9,000 Btu239.57,100 Btu/h11
H55FMHD6XPCMini/multi-split60,000 Btu18.5–22.59–9.541,000–42,000 Btu/h33
TMH55HEI2NAS0U25Mini/multi-split60,000 Btu22.59.542,000 Btu/h11
TMH55HEI2NAS0U25*Mini/multi-split60,000 Btu18.5–22.59–9.541,000–42,000 Btu/h33
H09SEH19BACMini/multi-split9,000 Btu199.57,300 Btu/h11
TSH09HEI1NAJ0X24*Mini/multi-split9,000 Btu199.57,300 Btu/h11
H18TDHXPCDucted1.5-ton179.518,000 Btu/h11
H24TDHXPCDucted2-ton179.524,000 Btu/h11
H30TDHXPCDucted2.5-ton179.530,000 Btu/h11
H36TDHXPCDucted3-ton179.536,000 Btu/h11
THH18TEI2NAG0F24Ducted1.5-ton179.518,000 Btu/h11
THH24TEI2NAG0F24Ducted2-ton179.524,000 Btu/h11
THH30TEI2NAG0F24Ducted2.5-ton179.530,000 Btu/h11
THH36TEI2NAG0F24Ducted3-ton179.536,000 Btu/h11
H36TDH18XACDucted3-ton19920,000–26,000 Btu/h33
THH36TEI2NAI0D24Ducted2.5-ton19920,000–26,000 Btu/h22
H48TDH18XACDucted4-ton188.5–933,000 Btu/h22
THH24TEI2NAI0H24Ducted2-ton18918,000 Btu/h11
H24TDH17XACDucted2-ton18–198.518,000–19,000 Btu/h22
THH48TEI2NAI0H24Ducted4-ton188.533,000 Btu/h11
H60TDH16XACDucted4.5-ton178.2–8.538,000 Btu/h22
THH60TEI2NAH0H24Ducted4.5-ton178.238,000 Btu/h11
THH24HES2NAGOH24Ducted2-ton15.2–168.118,000–19,000 Btu/h7878
THH36HES2NAGOH24Ducted3-ton15.2–168.127,000–30,000 Btu/h126126
THH48HES2NAGOH24Ducted3.5-ton15.2–168.137,000–38,000 Btu/h2222

Other TCL refrigerants: TCL R-32 · all TCL models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.