Refrigerant Finder

Kaden R-454B heat pumps and mini-splits

All 46 Kaden outdoor unit models on ENERGY STAR's list that use R-454B: 17 ducted, 29 mini or multi-split, 0 packaged, in 138 certified systems.

R-454B is a blend of R-32 and R-1234yf with a GWP of 470 in ENERGY STAR's data. Carrier, Bryant, Trane, American Standard, Rheem, Ruud, Bosch and many others moved their ducted lines to it when new R-410A split systems stopped being made on January 1, 2025. It is an A2L (mildly flammable) refrigerant, so the indoor coil or air handler must be designed and listed for it, and many systems need a refrigerant detection sensor.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
KOB-HH-PSX06HP-2AAMAMini/multi-split6,000 Btu22–25.512–14.87,700–8,100 Btu/h22
KOB-HH-PSX09HP-2AAMAMini/multi-split9,000 Btu20.5–27.412.1–13.810,600–11,900 Btu/h55
KOB-HH-PSX24HP-2AAMAMini/multi-split24,000 Btu19–2111.6–13.523,800–24,200 Btu/h33
KOB-PSX09HP-2AAMAMini/multi-split9,000 Btu19.5–25.811–12.58,000–8,600 Btu/h55
KOB-HH-PSX18HP-2AAMAMini/multi-split18,000 Btu18.4–21.411–12.317,000–18,000 Btu/h44
KOB-PSX18HP-2AAMAMini/multi-split18,000 Btu20–23.510.8–12.212,800–14,200 Btu/h44
KOB-PSX24HP-2AAMAMini/multi-split24,000 Btu19–2310.5–11.718,500–19,600 Btu/h33
KOB-HH-PSX12HP-2AAMAMini/multi-split12,000 Btu20–25.410–11.611,500–12,000 Btu/h55
KOB-HH-PS548HP-2AAMAMini/multi-split48,000 Btu20.4–231147,000–48,000 Btu/h33
KOB-HH-PS648HP-2AAMAMini/multi-split48,000 Btu20.4–231147,000–48,000 Btu/h33
KOB-HH-UUX30HP-2AAMADucted2.5-ton16.8–17.210–10.832,600–33,200 Btu/h22
KOB-HH-PS436HP-2AAMAMini/multi-split36,000 Btu19.4–2310.4–10.736,000–38,000 Btu/h33
KOB-HH-PS536HP-2AAMAMini/multi-split36,000 Btu19.4–2310.4–10.736,000–38,000 Btu/h33
KOB-HH-PS555HP-2AAMAMini/multi-split48,000 Btu20–22.210.5–10.747,000–48,000 Btu/h33
KOB-HH-PS655HP-2AAMAMini/multi-split48,000 Btu20–22.210.5–10.747,000–48,000 Btu/h33
KOB-PSX12HP-2AAMAMini/multi-split12,000 Btu19–25.510–10.68,400–8,900 Btu/h55
KOB-HH-PS327HP-2AAMAMini/multi-split30,000 Btu19–239.5–10.527,000 Btu/h33
KOB-HH-PS427HP-2AAMAMini/multi-split30,000 Btu19–239.5–10.527,000 Btu/h33
KOB-HH-PSX33HP-2AAMAMini/multi-split30,000 Btu19.510.535,000 Btu/h11
KOB-HH-PSX36HP-2AAMAMini/multi-split30,000 Btu19.510.535,000 Btu/h11
KOB-HH-PS218HP-2AAMAMini/multi-split18,000 Btu20–2510–10.418,000–19,000 Btu/h33
KOB-HH-PS318HP-2AAMAMini/multi-split18,000 Btu20–2510–10.418,000–19,000 Btu/h33
KOB-HH-UUX18HP-2AAMADucted1.5-ton199.7–10.118,000–18,600 Btu/h22
KOB-PSX09HP-1AAMAMini/multi-split9,000 Btu25.4107,200 Btu/h11
KOB-PS218HP-2AAMAMini/multi-split18,000 Btu20–25.19.8–1013,500–14,600 Btu/h33
KOB-PS318HP-2AAMAMini/multi-split18,000 Btu20–25.19.8–1013,500–14,600 Btu/h33
KOB-HH-UUX24HP-2AAMADucted2-ton18.3–18.61020,600–21,600 Btu/h22
KOB-HH-UUX36HP-2AAMADucted3-ton16.5–17.78.2–1032,000–32,600 Btu/h22
KOB-UUX24HP-2AAMADucted2-ton18.19.721,600 Btu/h11
KOB-PS327HP-2AAMAMini/multi-split24,000 Btu21–259–9.518,800–19,000 Btu/h33
KOB-PS427HP-2AAMAMini/multi-split24,000 Btu21–259–9.518,800–19,000 Btu/h33
KOB-PS436HP-2AAMAMini/multi-split36,000 Btu20–249.2–9.526,000 Btu/h33
KOB-PS536HP-2AAMAMini/multi-split36,000 Btu20–249.2–9.526,000 Btu/h33
KOB-PSX12HP-1AAMAMini/multi-split12,000 Btu23.49.57,700 Btu/h01
KOB-HH-UUX48HP-2AAMADucted4-ton16.5–17.59.546,000–48,000 Btu/h22
KOB-HH-UUX60HP-2AAMADucted4.5-ton16–17.59–9.552,000–54,000 Btu/h22
KOB-UUX18HP-2AAMADucted1.5-ton18.89.111,200 Btu/h01
KOB-UUX36HP-2AAMADucted3-ton16.18.727,000 Btu/h11
KOB-UUX48HP-2AAMADucted4-ton168.538,000 Btu/h11
KOB-UUX60HP-2AAMADucted4.5-ton15.28.438,000 Btu/h11
KOVH-18BAM152LDucted1.5-ton15.27.87,200–7,500 Btu/h06
KOVH-24BAM152LDucted2-ton15.27.810,000–10,200 Btu/h06
KOVH-30BAM152LDucted2.5-ton15.27.811,600–12,100 Btu/h08
KOVH-36BAM152LDucted3-ton15.27.816,900 Btu/h04
KOVH-42BAM152LDucted3.5-ton15.27.820,200 Btu/h04
KOVH-48BAM152LDucted4-ton15.27.821,400–21,600 Btu/h05

Other Kaden refrigerants: Kaden R-410A · all Kaden models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.