Refrigerant Finder

Haxxair R-410A heat pumps and mini-splits

All 13 Haxxair outdoor unit models on ENERGY STAR's list that use R-410A: 3 ducted, 10 mini or multi-split, 0 packaged, in 23 certified systems.

R-410A (GWP 2,088) was the standard for split heat pumps until EPA's Technology Transitions rule stopped the manufacture and import of new R-410A split systems on January 1, 2025. EPA's May 2026 final rule lets systems whose components were all made or imported before 2025 keep being installed until that stock runs out. New York's own rule (6 NYCRR Part 494) still bars new R-410A split-system installs from January 1, 2026.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
HVH-12T2DMini/multi-split12,000 Btu219.58,400 Btu/h01
HVHM-18T2DMini/multi-split18,000 Btu19–219.4–9.518,000 Btu/h55
HVHD-36E2D2Ducted3-ton189.526,000 Btu/h11
HVHM-24T2DMini/multi-split24,000 Btu21–228.6–9.124,000 Btu/h33
HAH-09T2DMini/multi-split9,000 Btu2296,300 Btu/h11
HVH-09T2DMini/multi-split9,000 Btu2296,300 Btu/h11
HVHM-36T2DMini/multi-split30,000 Btu19.5–218.9–936,000 Btu/h33
HVHD-24E2D2Ducted2-ton16.5916,900 Btu/h11
HVHM-42T2DMini/multi-split42,000 Btu18–208.8–8.936,000 Btu/h33
HVH-18T2DMini/multi-split18,000 Btu22.58.612,700 Btu/h11
HAH-24T2DMini/multi-split24,000 Btu20.58.618,000 Btu/h11
HVH-24T2DMini/multi-split24,000 Btu20.58.618,000 Btu/h11
HVHD-48E2D2Ducted4-ton17.58.533,000 Btu/h11

Other Haxxair refrigerants: Haxxair R-454B · all Haxxair models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.