All 33 Goodman outdoor unit models on ENERGY STAR's list that use R-410A: 14 ducted, 19 mini or multi-split, 0 packaged, in 139 certified systems.

R-410A (GWP 2,088) was the standard for split heat pumps until EPA's Technology Transitions rule stopped the manufacture and import of new R-410A split systems on January 1, 2025. EPA's May 2026 final rule lets systems whose components were all made or imported before 2025 keep being installed until that stock runs out. New York's own rule (6 NYCRR Part 494) still bars new R-410A split-system installs from January 1, 2026.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
MSH123G26MCAAMini/multi-split12,000 Btu27.514.513,500 Btu/h11
MSH093G26MCAAMini/multi-split9,000 Btu291413,500 Btu/h11
MSH093E23MCAAMini/multi-split9,000 Btu20.2–2510.3–129,800–10,800 Btu/h46
MSH093G22MCAAMini/multi-split9,000 Btu26.411.611,000 Btu/h11
MSH183E23MCAAMini/multi-split18,000 Btu18–21.59.5–11.316,000–18,000 Btu/h57
MSH183F25MCAAMini/multi-split18,000 Btu18–21.59.5–11.316,000–18,000 Btu/h35
MSH183G26MCAAMini/multi-split18,000 Btu26.31124,000 Btu/h11
MST363G22MHAAMini/multi-split36,000 Btu19.4–2110–10.936,000 Btu/h33
MSH183G22MCAAMini/multi-split18,000 Btu18–229.5–10.616,000–17,700 Btu/h33
MSH123G22MCAAMini/multi-split12,000 Btu19.5–23.110–10.511,000–12,100 Btu/h33
MSH243G22MCAAMini/multi-split24,000 Btu19.2–22.310.3–10.523,000–27,000 Btu/h22
MSH243E23MCAAMini/multi-split24,000 Btu18.9–19.210.4–10.523,400–27,000 Btu/h44
MSH123E23MCAAMini/multi-split12,000 Btu19.5–25.59.5–10.410,000–12,100 Btu/h77
MST483G22MHAAMini/multi-split48,000 Btu20.9–21.29–1042,500–45,000 Btu/h33
MST273G22MHAAMini/multi-split24,000 Btu19–20.59.6–1027,000 Btu/h33
MST283G22MHAAMini/multi-split30,000 Btu20–22.69.5–9.825,000 Btu/h33
MST183G22MHAAMini/multi-split18,000 Btu19–20.59–9.318,000–19,000 Btu/h33
MSH303G20MCAAMini/multi-split30,000 Btu218.720,000 Btu/h01
MSH183G20MCAAMini/multi-split18,000 Btu19.58.711,700 Btu/h01
GSZV902410A*Ducted2-ton218.213,100 Btu/h02
GSZV903610A*Ducted3-ton198.224,400 Btu/h07
GSZV904810A*Ducted4-ton198.225,400 Btu/h02
GSZC702410A*Ducted2-ton17.28.1–8.211,000 Btu/h011
GSZC703610A*Ducted3-ton17.28.1–8.217,000 Btu/h011
GSZC704810A*Ducted4-ton16.5–17.28.222,000 Btu/h08
GSZC706010A*Ducted4.5-ton15.2–16.28.1–8.230,000 Btu/h06
GSZH501810A*Ducted1.5-ton15.27.87,800 Btu/h06
GSZH502410A*Ducted2-ton15.27.811,300 Btu/h04
GSZH503010A*Ducted2.5-ton15.27.813,600 Btu/h04
GSZH503610A*Ducted3-ton15.27.817,600 Btu/h06
GSZH504210A*Ducted3.5-ton15.27.819,000 Btu/h04
GSZH504810A*Ducted4-ton15.27.819,800 Btu/h06
GSZH506010A*Ducted4.5-ton15.27.821,600 Btu/h04

Other Goodman refrigerants: Goodman R-32 · all Goodman models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.