Refrigerant Finder

Cooper&Hunter R-454B heat pumps and mini-splits

All 44 Cooper&Hunter outdoor unit models on ENERGY STAR's list that use R-454B: 11 ducted, 33 mini or multi-split, 0 packaged, in 186 certified systems.

R-454B is a blend of R-32 and R-1234yf with a GWP of 470 in ENERGY STAR's data. Carrier, Bryant, Trane, American Standard, Rheem, Ruud, Bosch and many others moved their ducted lines to it when new R-410A split systems stopped being made on January 1, 2025. It is an A2L (mildly flammable) refrigerant, so the indoor coil or air handler must be designed and listed for it, and many systems need a refrigerant detection sensor.

Outdoor unitTypeSizeSEER2HSPF2Heat at 5°FCold-climate pairingsCertified pairings
CH-RHP06F9-230VOMini/multi-split6,000 Btu21.4–25.512–14.87,500–8,100 Btu/h77
CH-RES09-230VOMini/multi-split9,000 Btu19.5–2611–13.98,000–8,600 Btu/h1010
CH-RES18-230VOMini/multi-split18,000 Btu18.5–249.8–13.512,800–14,000 Btu/h1111
CH-RHP24-230VOMini/multi-split24,000 Btu18.7–22.310–13.523,600–24,200 Btu/h99
CH-RHP09-230VOMini/multi-split9,000 Btu21.4–27.410.9–12.510,600–11,500 Btu/h1010
CH-RHP18-230VOMini/multi-split18,000 Btu18–21.710–12.317,000–18,000 Btu/h1111
CH-RES24-230VOMini/multi-split24,000 Btu19–23.59–11.717,800–19,600 Btu/h99
CH-RHP12-230VOMini/multi-split12,000 Btu20–25.410–11.611,300–11,800 Btu/h1010
CH-RES12-230VOMini/multi-split12,000 Btu19–25.510–11.58,400–8,900 Btu/h1010
CH-RHP36LCU-230VOMini/multi-split36,000 Btu17.2–21.29.5–11.137,000–39,500 Btu/h55
CH-RVHP48M-230VOMini/multi-split48,000 Btu20.4–231147,000–48,000 Btu/h33
CH-RHP15-230VOMini/multi-split18,000 Btu21.41118,000 Btu/h22
CH-PQ18-230VODucted1.5-ton15.8–19.39.5–10.818,000–19,600 Btu/h55
CH-RHP48LCU-230VOMini/multi-split48,000 Btu16.7–18.510.1–10.846,000–47,500 Btu/h55
CH-PQ33-230VODucted2.5-ton16–17.59.2–10.830,000–33,200 Btu/h66
CH-RES06-115VOMini/multi-split9,000 Btu24.510.77,300 Btu/h11
CH-RES09-115VOMini/multi-split9,000 Btu24.510.77,300 Btu/h22
CH-RVHP36M-230VOMini/multi-split36,000 Btu19.4–2310.4–10.736,000–38,000 Btu/h33
CH-RVHP55M-230VOMini/multi-split48,000 Btu20–22.210.5–10.747,000–48,000 Btu/h33
CH-RHP60LCU-230VOMini/multi-split48,000 Btu15.2–189.2–10.753,000–54,000 Btu/h33
CH-R48MES-230VOMini/multi-split48,000 Btu20.4–2410.3–10.636,000–38,000 Btu/h33
CH-RVHP28M-230VOMini/multi-split30,000 Btu19–239.5–10.527,000 Btu/h33
CH-RHP33-230VOMini/multi-split30,000 Btu19.5–2010.534,600–35,000 Btu/h33
CH-PQ24-230VODucted2-ton16–18.68.5–10.519,600–21,000 Btu/h88
CH-RVHP19M-230VOMini/multi-split18,000 Btu20–2510–10.418,000–19,000 Btu/h33
CH-RES12-115VOMini/multi-split12,000 Btu23.210.47,300 Btu/h02
CH-R36LCU-230VOMini/multi-split36,000 Btu2010.326,600 Btu/h22
CH-R48LCU-230VOMini/multi-split48,000 Btu17.1–19.89.8–10.235,200–38,500 Btu/h55
CH-R18MES-230VOMini/multi-split18,000 Btu20–25.19.8–1013,500–14,600 Btu/h33
CH-PQ36X-230VODucted3-ton15.8–189.4–1034,600–37,400 Btu/h44
CH-PQ36-230VODucted3-ton17.71032,600 Btu/h11
CH-R28MES-230VOMini/multi-split24,000 Btu21–259–9.518,800–19,000 Btu/h33
CH-R36MES-230VOMini/multi-split36,000 Btu20–249.2–9.526,000 Btu/h33
CH-REL30-230VOMini/multi-split30,000 Btu17–22.38.7–9.520,000–20,400 Btu/h04
CH-PQ48-230VODucted4-ton15.2–17.58.5–9.541,000–48,000 Btu/h33
CH-PQ55-230VODucted4.5-ton15.2–17.58.1–9.543,000–54,000 Btu/h33
CH-RLS24MIA-230VOMini/multi-split24,000 Btu18.79.317,000 Btu/h11
CH-ALT30HP24V-230VODucted2.5-ton17.69.221,200 Btu/h11
CH-RLS09MIA-230VOMini/multi-split9,000 Btu21.29.17,000 Btu/h11
CH-RLS06MIA-115VOMini/multi-split9,000 Btu21.596,500 Btu/h01
CH-RLS09MIA-115VOMini/multi-split9,000 Btu21.596,500 Btu/h01
CH-ALT24HP24V-230VODucted2-ton16.48.716,300 Btu/h11
CH-ALT48HP24V-230VODucted4-ton15.28.233,600 Btu/h11
CH-ALT60HP24V-230VODucted4.5-ton168.137,800 Btu/h11

Other Cooper&Hunter refrigerants: Cooper&Hunter R-410A · all Cooper&Hunter models

Not a guaranteed match. These are ENERGY STAR certified combinations as published by EPA. Before you buy, ask a licensed installer to confirm the exact outdoor unit, indoor coil or air handler and furnace, and check the AHRI certificate for that combination. Refrigerant work requires an EPA Section 608 certified technician.

Next step

Some links are affiliate links; we may earn a commission at no cost to you. Disclosure.